            当前位置: 医疗设备 > >监护仪

            产品订制服务

            公司大多数产品均可提供包括产品材质、产品型号、产品功能、产品包装等全方位定制服务。具体请咨询客服人员。

            我们通过十几年的医疗和健康产品出口服务,积累了丰富的行业经验,可根据客户需求,通过提供专业和个性化服务满足全球不同客户对个性化及品牌化订制医疗产品的需求。

            监护仪
            产品参数
            • Type:
            • First-Aid Devices
            • Brand Name:
            • Hiprove
            • Model Number:
            • HPL-9000
            • Place of Origin:
            • Shandong, China (Mainland)
            • Product name:
            • Medical Portable ICU Patient Monitor with good price ISO CE approved
            • Certificate:
            • CE ISO
            • Warranty:
            • 1 year
            • Size:
            • 12.1"
            • Display:
            • Multi channel display
            •  
            包装和交付
            • 包装细节:
            • 422637cm, 1 set/carton
            • 交货时间:
            • Shipped in 30 days after payment
            详情介绍

            Medical Portable ICU Patient Monitor with good price

             

            Features:

            12.1" color TFT LCD screen, resolution: 800*600
            5 kinds of interfaces: Standard/Big font/6-lead ECG/Trend gragh/OxyCRG
            Maximum 8-channel waveforms display, the waveform color can be defined by user (7 colors)
            96-hour storage and review of trend graphic gram and table, 400 groups NIBP data, 1800 alarm events
            ST and arrhythmia analysis, pacemaker analysis, drug dose calculation
            Anti-defibrillation design
            NIBP over pressure protection
            Plug-in rechargeable battery, AC/DC available
            Support wire or wireless network

            Standard: 3/5-Lead ECG, RESP, SpO2, NIBP, PR, TEMP

            Options: Nellcor SpO2, Mainstream/Sidestream EtCO2, 1/2 channel IBP, Touch screen,

            Thermal Recorder, Wall mount, Trolley

             

            Technical Specifications:

            ECG
            Lead Mode: 5 Leads (R, L, F, N, C or RA, LA, LL, RL,V)
            Lead selection: I, II, III, avR, avL, avF, V
            Wavef orm: 2 ch
            Lead mode: 3 Leads ( R, L, F or RA, LA, LL)
            Lead selection: I, II, III,
            Wave form: 1 ch
            Gain: 2.5mm/mV, 5.0mm/mV,
            10mm/mV,20mm/mV, auto
            HR and Alarm Range: Adult 15 ~ 300 bpm
            Neo/Ped 15 ~ 350 bpm

            Accuracy: ±1% or±1bpm, which is greater
            Resolution: 1 bpm
            Sensitivity: > 200 (uVp-p)
            Differential Input Impedance: > 5 MΩ

            CMRR : Monitor > 105 dB
            Operation > 105 dB
            Diagnosis > 85 dB
            Electrode offset potential: ±300mV
            Leakage Current: < 10 uA
            ECG Signal Range: ±8 m V ( Vp-p )
            Bandwidth:
            Surgery: 1 ~ 20 Hz
            Monitor: 0.5 ~ 40 Hz
            Diagnostic: 0.05 ~ 130 Hz
            Calibration Signal: 1 (mVp-p), Accuracy:5%
            ST Segment Monitoring Range
            Measure and Alarm -2.0 ~ +2.0 mV
            ARR Detecting:
            Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY,
            TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP,
            PNC,Alarm Available,Review Available


            RESP

            Method : Impedance between R-F(RA-LL)
            Differential Input Impedance: > 2.5 MΩ
            Measuring Impedance Range: 0.3~3 Ω
            Base line Impedance Range: 200~4 KΩ
            Bandwidth: 0.1~2.5Hz
            Resp. Rate:
            Measuring and Alarm Range
            Adult 0 ~ 120 Brpm
            Neo/Ped 0 ~ 150 Brpm
            Resolution 1 Brpm
            Accuracy ±2 Brpm
            Apnea Alarm: 10 ~ 40 S

             

            NIBP

            Method: Oscillometric
            Mode: Manual, Auto, STAT
            Measuring Interval in AUTO Mode :
            1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
            Measuring Period in STAT Mode: 5 Min
            Pulse Rate Range : 40 ~ 240 bpm
            Alarm Type : SYS, DIA, MEAN
            Measuring and alarm range:
            Adult Mode
            SYS: 40 ~ 270 mmHg
            DIA: 10 ~ 215 mmHg
            MEAN: 20 ~ 235 mmHg
            Pediatric Mode
            SYS: 40 ~ 200 mmHg
            DIA: 10 ~ 150 mmHg
            MEAN: 20 ~ 165 mmHg
            Neonatal Mode
            SYS: 40 ~ 135 mmHg
            DIA: 10 ~ 100 mmHg
            MEAN: 20 ~ 110 mmHg
            Resolution: 1mmHg
            Accuracy: Maximum Mean error ±5mmHg
            Maximum Standard deviation ±8mmHg
            Overpressure Protection
            Adult Mode: 297±3 mmHg
            Pediatric Mode: 240±3 mmHg
            Neonatal Mode: 147±3 mmHg
             

            SpO2
            Measuring Range: 0 ~ 100 %
            Alarm Range: 0 ~ 100 %
            Resolution: 1 %
            Accuracy: 70% ~ 100% 2 %
            0% ~ 69%
            Actualization intervalabout: 1 Sec.
            Alarm Delay: 10 Sec.
            Pulse Rate:
            Measuring and Alarm Range 20~300 bpm
            Resolution: 1bpm
            Accuracy: ±3bpm
             

            TEMP
            Channel: 2
            Measuring and Alarm Range : 0 ~ 50 ℃
            Resolution: 0.1 ℃
            Accuracy : ±0.2 ℃
            Actualization intervalabout: 1 Sec.
            Average Time Constant: < 10 Sec.


            IBP

            Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
            Measuring and alarm range:
            ART 0 ~ 300 mmHg
            PA -6 ~ 120 mmHg
            CVP/RAP/LAP/ICP-10 ~ 40 mmHg
            P1 / P2-10 ~ 300 mmHg
            Press Sensor:
            Sensitivity: 5 uV/V/mmHg
            Impedance: 300-3000Ω
            Resolution: 1 mmHg
            Accuracy: ±2% or 1mmHg which is greater
            Actualization interval : about 1 secretar
             

            Standard: ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
            Optional: Nellcor SpO2, EtCO2, IBP,TEMP-2, Thermal Recorder,Wall Mount,Trolly,Central station

             

             

            对此产品感兴趣,请给我们留言

            微信:ap277677188

            sss